PipeGuard Typical volumes and pressures for small HP gas in elastomer bladder type pulsation dampers.
Type / Ordering Volume Design Pressure @93 C Connections (to pump / to sys.) BS4504 DIN 2501 / ANSI B 16.5 Length without pipes Diameter Weight Spares Kit Part Number
  (Liters) (Bar)     (mm) (mm) (kg)  
PiG-** .1 345 3/8"Fx1/4"FN 1/2" 250# 181 64 6 B44x75 ?
PiG-SS .25 310 1/2"Fx3/8"FN 4x3/8" on 2.25" PCD 217 71 10 B57x98 ?
PiG-SS .65 172 3/4"Fx1/2"FN 4x1/2" on 2.5" PCD 282 89 15 B62x207 ?
PipeGuard Typical volumes and pressures for medium HP gas in elastomer bladder type pulsation dampers.
Type / Ordering Volume Design Pressure @93 C Connections (to pump / to sys.) BS4504 DIN 2501 / ANSI B 16.5 Length without pipes Diameter Weight Spares Kit Part Number
  (Liters) (Bar)     (mm) (mm) (kg)  
PiG-SS 1.25 172 1.0"Fx3/4"FN 4x1/2" on 2.5" PCD 432 88 22 B72x315 ?
PiG-SS 1.5 186 1.25"Mx1.0"FN 4x3/4" on 3.5" PCD 350 114 25 B98x232 ?
PiG-SS 2 186 1.5"Mx1.5"MN 4x3/4" on 3.5" PCD 405 114 27 B98x300 ?
PiG-SS 2.8 159 2.0"Mx1.5"MN DN20PN258 / 1" 1500# 365 141 36 B123x250
PiG-SS 3.28 159 2.0"Mx2.0"MN DNMPN291 / 1" 1500# 418 141 40 B123x295
PiG-SS 2 172 3.0"Mx2.0"MW DN25PN410 / 1" 2500# 300 170 30 B139x105
PiG-SS 3.9 172 3.0"Mx2.0"MW DN25PN410 / 1" 2500# 399 170 37 B139x205
PipeGuard Typical volumes and pressures for large HP gas in elastomer bladder type pulsation dampers.
Type / Ordering Volume Design Pressure @93 C Connections (to pump / to sys.) BS4504 DIN 2501 / ANSI B 16.5 Length without pipes Diameter Weight Spares Kit Part Number
  (Liters) (Bar)     (mm) (mm) (kg)  
PiG-SS 4 159 2.0"Mx2.0"MN DNMPN291 / 1" 1500# 470 141 45 B123x357
PiG-SS 8 172 3.0"Mx2.0"MW DN25PN410 / 1" 2500# 610 170 46 B139x420
PiG-SS 11.4 241 3"Mx3"MW DN65PN250 / 2" 1500# 610 219 96 B195x360
PiG-SS 20 241 3"Mx3"MW DN80PN250 / 2.5" 2500# 762 273 177 B230x500
PiG-SS 35 241 4"Mx4"MW DN100PN160 / 3" 2500# 914 324 286 B260x600
PiG-SS 50 172 5"Mx5"MW DN150PN250 / 4"1500# 1067 356 340 B300x700

 

Ultra High Pressure Gas in Elastomer Bladder Type Pulsation Damper Sizes HOME


Pulsation Dampers - Gas in Bladder

Low Pressure | Plastic and Aluminum | High Pressure


PipeGuard Typical volumes and pressures for small ultra HP gas in elastomer bladder pulsation dampers.
Type / Ordering Volume Design Pressure @93 C Connections (to pump / to sys.) BS4504 DIN 2501 / ANSI B 16.5 Length without pipes Diameter Weight Spares Kit Part Number
  (Liters) (Bar)     (mm) (mm) (kg)  
PiG-SS .016 517 1/4"x1/4"FN Not Applicable 117 45 3 B24x50 ?
PiG-SS .032 517 1/4"x1/4"FN Not Applicable 152 45 4 B24x80 ?
PiG-DSS .1 1035 3/8"x1/4"M AE 4x1/2" on 2.5" PCD 191 89 17 B44x75 ?
PiG-DSS .25 776 1/2"x3/8"M AE 4x5/8" on 2.75" PCD 254 102 26 B57x98 ?
PiG-SDSS 1 759 1.0"x3/4"M AE or H 1/2"2500# 406 130 70 B72x255 ?

 


Phone: 44 161 480 9625 • UK Freephone: 08080 LO PRICE (56 77423) • Fax: 44 161 480-9627
Pulsation Damper RFQ



























click here for clickable pictures of pumps, systems, & pulsation dampers.

Pulsation Damper Drawings   PulseGuard Limited is in Europe

Flow fluctuation & pulse interception type pulse dampers, which guard against pressure pulsation using PulseGuard pressure vessel design technology. PulseGuard pulsation dampeners, hydraulic accumulators, or surge suppressors dampen pressure pulsation & smooth system flow because they do not allow pressure pulses to bypass dampening chamber by use of a “T”. Our high efficiency pulsation dampeners design ensures 300% more performance size for size than “T piece” pressure vessel designs. We provide smooth system flow & pressure pulse damping, while saving you cost of installing a extra "T".

"Pulsation dampeners that do, fluid flow goes through, but pressure pulsation does not"

Pulsation Dampers From Inventory:

Liquid in bladder
dampners have a large diameter liquid chamber, relative ports, dissipate pressure waves, large diameter bladder design responds even at 0.05 Bar. Corrosive liquids go inside bladder, saving cost of Titanium, Hastelloy, Tantalum, etc. external pressure vessel shells.
Gas in bladder
type for low, medium, high, super, & extreme pressure, gas in bag (bladder) pulse dampener in stainless, steel, or plastic, design includes bladder internal web stabilization.
Flow-through flex-tube
pulsation dampeners for sludge, slurries, high viscosity, & liquids containing particulate. For pipe sizes: 0.75" through 14, pressure pulse / flow fluctuation attenuating capability, straight-line "clear-flow" path from in to out.
PTFE diaphragm
pulsation dampeners designed for use where double layer / "sandwich" PTFE diaphragm head metering pumps are required for hermetically sealed toxic, pyroforic, or hazardous duty.
No moving parts,
acoustic, bladderless, foamless pulse dampeners / pressure pulsation filters.
Food & drug
smooth, clean, or polished pressure vessels for use in hygienic & food grade industry applications including: viscous liquids & slurries, clean in place, temperature regulated (thermal jacketed or insulated), high pressure liquid chromatography (hplc), among others.

 



cheap makeup wholesale fitflop singapore sale cheap pandora charms pandora charms sale uk cheap urban decay makeup spotify to mp3 12 sided fidget cube cheap mac makeup uk cheap nba jerseys australia cheap nba jerseys cheap nba jerseys uk cheap authentic nfl jerseys for sale replica sunglasses outlet uk
 Pulsation Damper Distributors
Low Pressure PTFE Membrane Types High Pressure PTFE Diaphragm Dampers Bladder Accumulators / Pulsation Dampeners Elastomer Bladder Dampers / PipeHugger Low Pressure Elastomer Bladder Damper / PipeHugger High Pressure Flow Through Flexible Tubes / PumpGuard
PulseGuard
PulseGuard Pulsation Dampers
International: --44 (0) 161-480-9625
UK Free Phone: 08080 LO-PRICE (56-77423)
Email: PG.Stabilizers.Sales.UK@Gmail.com
Pulsation Dampers | Pulse Damper Drawings
PulseGuard Pump Pulsation Dampers PulseGuard Pulsation Dampers PulseGuard Ltd. Pulsation Dampers Dampners from stock, for United Kingdom - Europe - and Asia
It is predicted that the replica watches uk two sides will issue a strong warning to the rolex replica DPRK, and stressed that by virtue of the United States and South Korea alliance replica watches strong defense against North Korea.

Copyright © 2024 PulseGuard. | PulseGuard is the UK trademark of PulseGuard Limited and the US trademark of PulseGuard Inc..