Pulsation Damper Information PDFPDF PG24 Power Pulsation Damper Part Numbers Printable Version

Pulsation Dampers Sizes - Multiplex Power Pumps / Connections / Part Numbers

Pulsation Damper Size Selection Tables for use with Multiplex "Power Pumps"

1. Dampers listed below are from 1000s of "off the shelf" inventory dampers. Call toll free 1-888-DAMPERS (326-7377) for discounts etc. Choose a damper matching your pump connection size, for standard damping. Or allow us to calculate for you, from your smoothness required and your system data.
2. Where there is no occupational health and safety need for in place flush through before servicing, nor any process requirement for constant temperature, or first in first out need to control residence time, not even clean before changing liquids it is still least expensive to use a standard twin connection damper, & save a "T". Use the other connection for the system drain, relief valve, or branch line. Waveguard and DAMPERS for frequencies above 10Hz., and or systems in which pipe-run or tube nodes are less than 290 meters /950ft have to be "Flow-Through"

Pulsation Damper Site - Arrow Drawings below

INSTRUCTIONS:
4. Please choose the damper part number from the table , which has the same connection size as your pump.
5. We have made these "pre-engineered" selections for you, on the basis of 40 years experience, and average
application circumstances.
6. Please call us toll-free 1-888-DAMPERS (326-7377) with the part number chosen from the tabulation. We will then
find the current price for you.

Pulsation Damper for Viscous Flow, Slurry, and Semi-Solids - PumpGuard
For Suction Systems, No N2 or Air Pre-Fill required. Remove volumetric acceleration head losses. * see foot of page

With Ceramics No Moving Parts, No N2 Or Air Pre-Fill required
Pulsation Damper with Liquid Elastomer Bladder - High Pressure Pulsation Interceptor/Isolators, liquid in bladder. * See foot of page
Pulsation Damper with Liquid Elastomer Bladder - Low Pressure
No flow reversal pressure loss in a single connection. Perfect suction acceleration head loss recovery.
For Discharge Pulsation Damper with Elastomer Bladder - Low Pressure PipeGuardfor Suction
The original 1965 One piece molded gas bags, in all stainless hells from the originators. Available connections to 15,000 psi with GL / SBL Hubs, or Autoclave/PPI. For use in externally corrosive environments. See Accumulators-hyd.com

Pulsation Dampers Installed Correctly Increase Performance


PUMPS make FLOW, SYSTEMS cause PRESSURE, pressure pulsation is a system response, AND a system responsibility NOT a pump manufacturers liability.