Pulsation Damper Information PDF PDF PG72 Pulsation Damper Application Story

Pulsation Dampers - Packed Plunger Pump Application

Even with the exceptional PACKED PLUNGER PUMP SUCTION LIFT CAPABILITY
from minimum dead volume, slow long stroke and small plunger diameter,
there are still - FILLING PROBLEMS - galore!

TECH NOTE: (not necessary to read these highlighted areas)
1 "Pads" of pressurized nitrogen gas are applied to the supply tanks, as soon as the pressure falls below the pressure at which the pad saturated the liquid, the gas comes back out of solution, and simulates cavitation so unless you provide a suction boost pump as well, every suction stroke begins with a loss of volume into the pump and a potential fall in output.

PROBLEM
A blowing agent (like pentane) is chilled and transferred into a supply tank. It warms a little, and the vapor pressure provides a supply "suction head pressure". The liquid is at vapor pressure! The liquid will only move to the pump suction check valve if the pressure at the check valve is lower than where it came from. So at the pump it is below vapor pressure. The pump doesn't fill. The height of the tank is enough head to overcome the flow friction, most of that benefit is lost by further warming as it travels the pipe.

ANSWER
(1) Cooling jacked damper brings temperature below vapor pressure @ temperature.
(2) The damper sized to recover 96% of the suction mass acceleration head loss.
(3) Damper with flow through to save flow reversal loss (that occurs with a "T" connection), AND which keeps the temperature constant - warm in - cool out.

Pipe Hugger Pulsation Damper
Pipe Hugger Pulsation Damper

Smooth Dosing Pulsation Damper
Smooth Dosing Pulsation Damper
THE RULE OF "2:6:3:1" ratio of cross sectional areas inside the pipes. More flow and pressure stabilization is achieved by having: 1) A pipe sized for 0.6 meters per sec. constant velocity to the suction damper. 2) A pipe sized for peak velocity from suction damper to pump inlet check valve. 3) Pipe for peak velocity from pump discharge to damper. 4) Sized for 3 meters per sec from damper for the system.

RESULTS
In less than 2 weeks, & under $600
(1) The constant velocity caused in the supply line, enables a pipe size reduction, which reduces time in the pipe & so reduces the warming even further.
(2) Metering accuracy increase - 9% deviation down to 1/2%, consistent foam, and save excess blowing agent.
(3) Stopped "finger pointing" at pump, & didn't need a new one.
3. The root cause of the problems was that because there was an "adequate" different between NPSHA and NPSHR to cover flow friction, it was assumed that the pump would fill. The NPSH approach assumed that the pump was centrifugal, positive displacement pumps are not centrifugal; reciprocating pumps need to avoid mass acceleration pressure loss for every stroke. A general term for this is "mass acceleration head" meaning pressure difference required to overcome the inertia of weight of the liquid in the pipe. This weight is obtained from the cross sectional area of the flow path, times length, to find volume times the specific gravity / density of the liquid = mass. Rate of acceleration times mass, gives force = Delta P.Liquid Dynamics International
 
First address the suction system, no pump can give you smooth flow unless it can fill properly.

Dampers that do, flow goes through, Pressure problems do not.

 



nba jerseys australia wholesale makeup cheap nfl jerseys replica sunglasses outlet uk
 Pulsation Damper Distributors
Low Pressure PTFE Membrane Types High Pressure PTFE Diaphragm Dampers Bladder Accumulators / Pulsation Dampeners Elastomer Bladder Dampers / PipeHugger Low Pressure Elastomer Bladder Damper / PipeHugger High Pressure Flow Through Flexible Tubes / PumpGuard
PulseGuard
PulseGuard Pulsation Dampers
International: --44 (0) 161-480-9625
UK Free Phone: 08080 LO-PRICE (56-77423)
Email: PG.Stabilizers.Sales.UK@Gmail.com
Pulsation Dampers | Pulse Damper Drawings
PulseGuard Pump Pulsation Dampers PulseGuard Pulsation Dampers PulseGuard Ltd. Pulsation Dampers Dampners from stock, for United Kingdom - Europe - and Asia

Copyright © 2017 PulseGuard. | PulseGuard is the UK trademark of PulseGuard Limited and the US trademark of PulseGuard Inc..