PulseGuard Pulsation Dampers
PulseGuard: Guarding Against Pulsation
Pump Pulsation Dampers
Fluid Flow Control Animations

Pulsation Damper Information PDF PDF PG64 HP Pulsation Damper Application Story

Pulsation Dampers - Packed Plunger Pump / You Choose the Efficiency

You chose the Efficiency of - a PACKED PLUNGER PUMP,
you have the least pressure pulsation - from a variable stroke metering pump
(Excluding "lost motion - limited back stock" machines).

TECH NOTE: (not necessary to read these highlighted areas)
The distance between the end of the plunger stoke, and the cylinder head, plus the volume in the suction and discharge check valve pockets, are together, less than a quarter of the dad volume of a diaphragm head pump, 1/4 the inefficiency of a diaphragm head.
Because of this high efficiency of plunger pumps, the liquid is accelerated progressively, prevents pressure shocks, & provides a smoother flow.

An extruder producing foam insulation for pipe cover, needs a constant feed of foaming agent. This is like a refrigerant. These foaming liquids are highly compressible, and despite the high efficiency of plunger pumps, in general, it is necessary to intercept the decompression shock wave with a "flow through" Pulsation Damper with Liquid Elastomer Bladder - PipeHugger.

PROBLEM
(1) Provide flow thru. in place flushability for extruder flush cycle.
(2) Intercept pressure transients @ 1300 meters/sec & 180 Hz.
(3) Reduce the 3 meter per second flow fluctuation to +-0.5%

ANSWER
A separate connection, in and out, "flow through", Pulsation Damper with Liquid Elastomer Bladder - PipeHugger 70 times the volume of one stroke of the pump, rated at 2250 psi (150 Bar) 3/8" pump connection & 1/8" system connection, available off the shelf.
Pulsation Damper - Packed Plunger Pump
Pulsation Damper - Packed Plunger Pump
THE RULE OF "2:6:3:1" ratio of cross sectional areas inside the pipes. More flow and pressure stabilization is achieved by having: 1) A pipe sized for 0.6 meters per sec. constant velocity to the suction damper. 2) A pipe sized for peak velocity from suction damper to pump inlet check valve. 3) Pipe for peak velocity from pump discharge to damper. 4) Sized for 3 meters per sec from damper for the system.
Pulsation Damper - High Pressure PipeHugger
Pulsation Damper - High Pressure PipeHugger
RESULTS
(1) The CORIOLIS (vibrating tube) mass transfer meter gives ACCURATE READINGS. Instead of being over excited at its natural frequency of 90 Hz.
(2) The ratio of damper inlet hole size to damper internal diameter is in excess of 1:6. This ratio gives a "discharge coefficient" which in effect KILLS THE PRESSURE PULSE. The residue of the pressure wave is prevented from escaping from the outlet by the even higher "convergence coefficient".
(3) The flow fluctuations are stabilized to LESS THAN A 1% FLOW SWING by the accumulation capability of the Nitrogen volume.
The right size of pipe, small enough to be "dissipative", does as much to stabilize flow fluctuations, and reduce pressure pulsation, & prevent resonance, as is achieved with "dampers",and smaller pipe costs less.
Liquid Dynamics International

Pulsation Dampers Installed Correctly Increase Performance

 



cheap makeup wholesale fitflop singapore sale cheap pandora charms pandora charms sale uk cheap urban decay makeup spotify to mp3 12 sided fidget cube cheap mac makeup uk cheap nba jerseys australia cheap nba jerseys cheap nba jerseys uk cheap authentic nfl jerseys for sale replica sunglasses outlet uk
 Pulsation Damper Distributors
Low Pressure PTFE Membrane Types High Pressure PTFE Diaphragm Dampers Bladder Accumulators / Pulsation Dampeners Elastomer Bladder Dampers / PipeHugger Low Pressure Elastomer Bladder Damper / PipeHugger High Pressure Flow Through Flexible Tubes / PumpGuard
PulseGuard
PulseGuard Pulsation Dampers
International: --44 (0) 161-480-9625
UK Free Phone: 08080 LO-PRICE (56-77423)
Email: PG.Stabilizers.Sales.UK@Gmail.com
Pulsation Dampers | Pulse Damper Drawings
PulseGuard Pump Pulsation Dampers PulseGuard Pulsation Dampers PulseGuard Ltd. Pulsation Dampers Dampners from stock, for United Kingdom - Europe - and Asia
It is predicted that the replica watches uk two sides will issue a strong warning to the rolex replica DPRK, and stressed that by virtue of the United States and South Korea alliance replica watches strong defense against North Korea.

Copyright © 2024 PulseGuard. | PulseGuard is the UK trademark of PulseGuard Limited and the US trademark of PulseGuard Inc..